14 research outputs found

    Timing performance of the Timepix4 front-end

    Full text link
    A characterisation of the Timepix4 pixel front-end with a strong focus on timing performance is presented. Externally generated test pulses were used to probe the per-pixel time-to-digital converter (TDC) and measure the time-bin sizes by precisely controlling the test-pulse arrival time in steps of 10 ps. The results indicate that the TDC can achieve a time resolution of 60 ps, provided that a calibration is performed to compensate for frequency variation in the voltage controlled oscillators of the pixel TDCs. The internal clock distribution system of Timepix4 was used to control the arrival time of internally generated analog test pulses in steps of about 20 ps. The analog test pulse mechanism injects a controlled amount of charge directly into the analog front-end (AFE) of the pixel, and was used to measure the time resolution as a function of signal charge, independently of the TDC. It was shown that for the default configuration, the AFE time resolution in the hole-collecting mode is limited to 105 ps. However, this can be improved up to about 60 ps by increasing the preamplifier bias-current at the cost of increased power dissipation. For the electron-collecting mode, an AFE time resolution of 47 ps was measured for a bare Timepix4 device at a signal charge of 21 ke. It was observed that additional input capacitance from a bonded sensor reduces this figure to 62 ps

    Timing performance of the LHCb VELO Timepix3 Telescope

    Full text link
    We performed a detailed study of the timing performance of the LHCb VELO Timepix3 Telescope with a 180 GeV/c mixed hadron beam at the CERN SPS. A twofold method was developed to improve the resolution of single-plane time measurements, resulting in a more precise overall track time measurement. The first step uses spatial information of reconstructed tracks in combination with the measured signal charge in the sensor to correct for a mixture of different effects: variations in charge carrier drift time; variations in signal induction, which are the result of a non-uniform weighting field in the pixels; and lastly, timewalk in the analog front-end. The second step corrects for systematic timing offsets in Timepix3 that vary from -2 ns to 2 ns. By applying this method, we improved the track time resolution from 438±\,\pm\,16 ps to 276±\,\pm\,4 ps

    Registration of the transition radiation with GaAs detector: Data/MC comparison

    Get PDF
    New developments of pixel detectors based on GaAs sensors offer effective registration of the transition radiation (TR) X-rays and perform simultaneous measurements of their energies and emission angles. This unique feature opens new possibilities for particle identification on the basis of maximum available information about generated TR photons. Results of studies of TR energy-Angular distributions using a 500 |j.m thick GaAs sensor attached to a Timepix3 chip are presented. Measurements, analysis techniques and a comparison with Monte Carlo (MC) simulations are described and discussed

    Detector Technologies for CLIC

    Full text link
    The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.Comment: 152 pages, 116 figures; published as CERN Yellow Report Monograph Vol. 1/2019; corresponding editors: Dominik Dannheim, Katja Kr\"uger, Aharon Levy, Andreas N\"urnberg, Eva Sickin

    The Compact Linear Collider (CLIC) - 2018 Summary Report

    Get PDF

    The Compact Linear Collider (CLIC) - 2018 Summary Report

    Get PDF
    The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear e+ee^+e^- collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years

    Development of a single-photon imaging detector with pixelated anode and integrated digital read-out

    No full text
    We present the development of a single-photon detector and the connected read-out electronics. This “hybrid” detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating the analog and digital-front end electronics. This assembly will be capable of detecting up to 109^{9} photons per second with simultaneous measurement of position and time.The pixelated read-out anode used is based on the Timepix4 ASIC (65 nm CMOS technology) designed in the framework of the Medipix4 collaboration. This ASIC is an array of 512 × 448 pixels distributed on a 55 μm square pitch, with a sensitive area of  ∼7 cm2^{2}. It features 50–70 e^{−} equivalent noise charge, a maximum rate of 2.5 Ghits/s, and allows to time-stamp the leading-edge time and to measure the Time-over-Threshold (ToT) for each pixel. The pixel-cluster position combined with its ToT information will allow to reach 5–10 μm position resolution. This information can also be used to correct for the leading-edge time-walk achieving a timing resolution of the order of 10 ps.The detector will be highly compact thanks to the encapsulated front-end electronics allowing local data processing and digitization. An FPGA-based data acquisition board, placed far from the detector, will receive the detector hits using 16 electro-optical links operated at 10.24 Gbps. The data acquisition board will decode the information and store the relevant data in a server for offline analysis.These performance will allow significant advances in particle physics, life sciences, quantum optics or other emerging fields where the detection of single photons with excellent timing and position resolutions are simultaneously required.We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating the analog and digital-front end electronics. This assembly will be capable of detecting up to 10910^9 photons per second with simultaneous measurement of position and time. The pixelated read-out anode used is based on the Timepix4 ASIC (65 nm65~\mathrm{nm} CMOS technology) designed in the framework of the Medipix4 collaboration. This ASIC is an array of 512×448512\times448 pixels distributed on a 55 μm55~\mathrm{\mu m} square pitch, with a sensitive area of 7 cm2\sim 7~\mathrm{cm}^2. It features 5050-70 e70~\mathrm{e^{-}} equivalent noise charge, a maximum rate of 2.5 Ghits/s2.5~\mathrm{Ghits/s}, and allows to time-stamp the leading-edge time and to measure the Time-over-Threshold (ToT) for each pixel. The pixel-cluster position combined with its ToT information will allow to reach 55-10 μm10~\mathrm{\mu m} position resolution. This information can also be used to correct for the leading-edge time-walk achieving a timing resolution of the order of 10 ps10~\mathrm{ps}. The detector will be highly compact thanks to the encapsulated front-end electronics allowing local data processing and digitization. An FPGA-based data acquisition board, placed far from the detector, will receive the detector hits using 1616 electro-optical links operated at 10.24 Gbps10.24~\mathrm{Gbps}. The data acquisition board will decode the information and store the relevant data in a server for offline analysis. These performance will allow significant advances in particle physics, life sciences, quantum optics or other emerging fields where the detection of single photons with excellent timing and position resolutions are simultaneously required

    Registration of the transition radiation with GaAs detector: Data/MC comparison

    Get PDF
    New developments of pixel detectors based on GaAs sensors offer effective registration of the transition radiation (TR) X-rays and perform simultaneous measurements of their energies and emission angles. This unique feature opens new possibilities for particle identification on the basis of maximum available information about generated TR photons. Results of studies of TR energy-angular distributions using a 500 um thick GaAs sensor attached to a Timepix3 chip are presented. Measurements, analysis techniques and a comparison with Monte Carlo (MC) simulations are described and discussed

    CERN Yellow Reports: Monographs, Vol 1 (2019): Detector Technologies for CLIC

    No full text
    The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D

    Updated baseline for a staged Compact Linear Collider

    Get PDF
    The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons
    corecore